9031035 E4 Event and Alarm Messages
9-7
Ungermann Bass Hub Events and Alarms
001b0065
Access/One hub model {m}: The interpreter
on the netcard has detected a logout
command on the service port.
Not applicable
001b0070
Access/One hub model {m}: A change in the
configuration of the hub cluster has
occurred, slot {I 2}, port {I 3}.
001b0070
1) A card has been inserted into the
hub.
2) A card has been removed from the
hub.
3) A port has been auto-partitioned
and forced detachment of the board
from the backplane bus by the
supervisor.
001b0072
Access/One hub model {m}: the hub has been
reset (not the management information).
001b0072
1) Operator intervention.
2) Supervisor intervention.
3) Manual reset.
001b0073
Access/One hub model {m}: the link status of
port {I 3}, slot {I 2}, has changed {I 4}.
001b0073
1) Operator intervention.
2) Supervisor intervention.
3) Manual reset.
001b0074
Access/One hub model {m}: SQE test on port
{I 3}, slot {I 2}, is not disabled.
Not applicable
Table 9-1. Events and Alarms (Continued)
Event Message Probable Cause Message