Hot Swapping a Switching Fabric Module (XP-8600 only)
30 Enterasys Xpedition User Reference Manual
2. Tighten the captive screws on each side of the Control Module or line card to secure it
to the chassis.
On a line card, the Online LED lights, indicating it is now active.
On a secondary Control Module, the Offline LED lights, indicating it is standing by to
take over as the primary Control Module if necessary.
Hot Swapping a Switching Fabric Module (XP-8600 only)
The XP-8600 has slots for two Switching Fabric Modules. While the XP-8600 is operating,
you can install a second Switching Fabric Module. If two Switching Fabric Modules are
installed, you can hot swap one of them.
When you remove one of the Switching Fabric Modules, the other goes online and stays
online until it is removed or the XP-8600 is powered off. When the XP-8600 is powered on
again, the Switching Fabric Module in slot “Fabric 1,” if one is installed there, becomes the
active Switching Fabric Module.
Warning: You can only hot swap a Switching Fabric Module if two are installed on the XP-
8600. If only one Switching Fabric Module is installed, and you remove it, the XP-8600 will
crash.
The procedure for hot swapping a Switching Fabric Module is similar to the procedure for
hot swapping a line card or Control Module. You deactivate the Switching Fabric Module,
remove it from the XP, and insert another Switching Fabric Module in the slot.
Note: You cannot deactivate the Switching Fabric Module with the system hotswap
command.
To deactivate the Switching Fabric Module:
1. Press the Hot Swap button on the Switching Fabric Module you want to deactivate.
The Online LED goes out and the Offline LED lights. Figure 4 shows the location of the
Offline LED and Hot Swap button on a Switching Fabric Module.
Figure 4. Location of Offline LED and Hot Swap Button on a Switching Fabric Module
SSR-SF-16
Switching Fabric
Active
Online
Swap
Hot
Offline
Offline LED
Hot Swap Button